Series EWS 1′ Simplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 1″ NPT inlet and outlet top mounted composite electronic control valve.
  • Electronic flow meter with accuracy within plus or minus 5 percent, flow rate range 0.25 to 27 gpm. Gallons range 20 to 50,000 gallons, 1000 to 9,999,000, totalizer.
  • Service flow rate up to 27 gpm, peak flow rate up to 32 gpm, backwash flow rates up to 27 gpm.
  • Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill and service.
  • Parallel flow, alternating on demand soft water.
  • Cycles of operation. Cycle One backwash 6-12 minutes, Cycle Two draw/slow rinse 45-75 minutes, Cycle Three second backwash 3-12 minutes, Cycle Four fast rinse 3-8 minutes, Cycle Five regeneranat refill (in service with treated water), Cycle Six service.
  • Four methods to initiate regeneration, meter immediate, meter delayed, time clock delayed or pressure differential.
  • 1″ water distribution system utilizing single point distributor or hub and laterals for maximum flowrates.
  • Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (totalizer).
  • Double backwash for optimum regeneration cleaning ability and salt efficiency.
  • 12 volt output AC transformer.
  • 1 – 28 day override on control valve programming.
  • Brine tank salt grid for easy cleaning.
  • Brine tanks 18″ x 33″ or 24″ x 50″ c./w brine well and safety float to eliminate overflowing tanks. The brine tank has 500lb or 800lb water softening salt capacity.
  • 1″ FPT drain line, 1/2″ FPT brine line.

Series EWS 1′ Duplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 1” NPT inlet and outlet top mounted composite electronic control valve.
  • Electronic flow meter with accuracy within plus or minus 5 percent, flow rate range
    0.25 to 27 gpm. Gallons range 20 to 50,000 gallons, 1000 to 9,999,000, totalizer.
  • Service flow rate up to 27 gpm, peak flow rate up to 32 gpm, backwash flow rates
    up to 27 gpm.
  • Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill and service.
  • Parallel flow, alternating on demand soft water.
  • Cycles of operation. Cycle One backwash 6-12 minutes, Cycle Two draw/slow
    rinse 45-75 minutes, Cycle Three second backwash 3-12 minutes, Cycle
    Four fast rinse 3-8 minutes, Cycle Five regeneranat refill (in service with treated
    water), Cycle Six service.
  • Four methods to initiate regeneration, meter immediate, meter delayed, time clock
    delayed or pressure differential.
  • 1” water distribution system utilizing single point distributor or hub and laterals for
    maximum flowrates.
  • Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F – 110°F
    (5°C – 44°C).
  • Solid state microprocessor c/w display for time of day, days until next regeneration,
    volume remaining, current flow rate and total volume used (totalizer).
  • Double backwash for optimum regeneration cleaning ability and salt efficiency.
  • 12 volt output AC transformer.
  • Duplex alternating motorized electronic control valve (1”).
  • 1 – 28 day override on control valve programming.
  • Brine tank salt grid for easy cleaning.
  • Brine tanks 18″ x 33″ or 24” x 50” c./w brine well and safety float to eliminate overflowing tanks.
    The brine tank has 500lb or 800lb water softening salt capacity.
  • 1” FPT drain line, 1⁄2” FPT brine line.

Series EWS 1.5′ Simplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 1 ½” NPT inlet and outlet top mounted lead free brass epoxy coated control valve.
  • Electronic flow meter with accuracy within plus or minus 5 percent, flow rate range 0.5 to 60 gpm. Gallons range 500 to 250,000, totalizer 1 to 9,999,000 gallons.
  • Service flow rate up to 60 gpm, peak flow rate up to 68 gpm, backwash flow rates up to 50 gpm.
  • Fully adjustable 6 cycle controls backwash, slow/fast rinse, draw, refill and service.
  • Soft water on demand.
  • Cycles of operation. Cycle One backwash 1-20 minutes or off, Cycle Two draw/slow rinse 1-99
    minutes or off, Cycle Three second backwash 1-20 minutes or off, Cycle Four fast rinse 1-20 minutes
    or off, Cycle Five regeneranat refill (in service with treated water) 0.1-99 minutes of off, Cycle Six service.
  • Four methods to initiate regeneration, meter immediate, meter delayed, time clock delayed or
    pressure differential.
  • 1 ½” water distribution system utilizing single point distributor or hub and laterals for maximum flowrates.
  • Operating pressure 20-125 psi / 138-861 kpa, operating temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (totalizer).
  • Double backwash for optimum regeneration cleaning ability and salt efficiency.
  • 12 volt output AC transformer.
  • 1 – 28 day override on control valve programming.
  • Brine tank salt grid for easy cleaning.
  • Brine tanks 24” x 50” or 30”x 50” c./w brine well and safety float to eliminate overflowing tanks.
    The brine tank has 800 or 1000lb water softening salt capacity.
  • 1 ¼” FPT drain line, ¾” FPT brine line.

Series EWS 1.5′ Duplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 1 ½” NPT inlet and outlet top mounted lead free
    brass epoxy coated control valve.
  • Electronic flow meter with accuracy within plus
    or minus 5 percent, flow rate range 0.5 to 60 gpm.Gallons range 500 to 250,000, totalizer
    1 to 9,999,000 gallons.
  • Service flow rate up to 60 gpm, peak flow rate
    up to 68 gpm, backwash flow rates up to 50 gpm.
  • Fully adjustable 6 cycle controls backwash,
    slow/fast rinse, draw, refill and service.
  • Parallel flow, alternating on demand soft water.
  • Cycles of operation. Cycle One backwash 1-20 minutes
    or off, Cycle Two draw/slow rinse 1-99 minutes or off,
    Cycle Three second backwash 1-20 minutes or off,
    Cycle Four fast rinse 1-20 minutes or off, Cycle Five
    regeneranat refill (in service with treated water)
    0.1-99 minutes of off, Cycle Six service.
  • Four methods to initiate regeneration, meter immediate,
    meter delayed, time clock delayed or pressure differential.
  • 1 ½” water distribution system utilizing single point distributor
    or hub and laterals for maximum flowrates.
  • Operating pressure 20-125 psi / 138-861 kpa, operating
    temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w display for time of day, days
    until next regeneration, volume remaining, current flow rate
    and total volume used (totalizer).
  • Double backwash for optimum regeneration cleaning ability
    and salt efficiency.
  • 12 volt output AC transformer.
  • Duplex alternating motorized electronic control
    valve (1 ½”).
  • 1 – 28 day override on control valve programming.
  • Brine tank salt grid for easy cleaning.
  • Brine tanks 24” x 50” or 30” x 50” c./w brine well and safety
    float to eliminate overflowing tanks.The brine tank has 800
    or 1000lb water softening salt capacity.
  • 1 ¼” FPT drain line, ¾” FPT brine line.

Series EWS 2.0′ L Simplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 2” NPT inlet and outlet top mounted lead free
    brass epoxy coated control valve.
  • Electronic flow meter with accuracy within plus
    or minus 5 percent, flow rate range 1.5 to 75 gpm.Gallons range 500 to 250,000, totalizer
    1 to 9,999,000 gallons.
  • Service flow rate up to 75 gpm, peak flow rate up
    to 88 gpm, backwash flow rates up to 50 gpm.
  • Fully adjustable 6 cycle controls backwash, slow/fast
    rinse, draw, refill and service.
  • Soft water on demand.
  • Cycles of operation. Cycle One backwash 1-20 minutes
    or off, Cycle Two draw/slow rinse 1-99 minutes or off,
    Cycle Three second backwash 1-20 minutes or off,
    Cycle Four fast rinse 1-20 minutes or off, Cycle Five
    regeneranat refill (in service with treated water)
    0.1-99 minutes of off, Cycle Six service.
  • Four methods to initiate regeneration, meter immediate,
    meter delayed, time clock delayed or pressure differential.
  • 1 ½” water distribution system utilizing single point
    distributor or hub and laterals for maximum flowrates.
  • Operating pressure 20-125 psi / 138-861 kpa, operating
    temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w display for time of day,
    days until next regeneration, volume remaining, current
    flow rate and total volume used (totalizer).
  • Double backwash for optimum regeneration cleaning
    ability and salt efficiency.
  • 12 volt output AC transformer.
  • 1 – 28 days override on control valve programming.
  • Brine tank salt grid for easy cleaning.
  • Brine tanks 24” x 50” or 30” x 50” c./w brine well and safety
    float to eliminate overflowing tanks.The brine tank has 800
    or 1000lb water softening salt capacity.
  • 1 ¼” FPT drain line, ¾” FPT brine line.

Series EWS 2.0″ L Duplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 2” NPT inlet and outlet top mounted lead free
    brass epoxy coated control valve.
  • Electronic flow meter with accuracy within plus
    or minus 5 percent, flow rate range 1.5 to 75 gpm.Gallons range 500 to 250,000, totalizer
    1 to 9,999,000 gallons.
  • Service flow rate up to 75 gpm, peak flow rate up
    to 88 gpm, backwash flow rates up to 50 gpm.
  • Fully adjustable 6 cycle controls backwash, slow/fast
    rinse, draw, refill and service.
  • Parallel flow, alternating on demand soft water.
  • Cycles of operation. Cycle One backwash 1-20 minutes
    or off, Cycle Two draw/slow rinse 1-99 minutes or off,
    Cycle Three second backwash 1-20 minutes or off,
    Cycle Four fast rinse 1-20 minutes or off, Cycle Five
    regeneranat refill (in service with treated water)
    0.1-99 minutes of off, Cycle Six service.
  • Four methods to initiate regeneration, meter immediate,
    meter delayed, time clock delayed or pressure differential.
  • 1 ½” water distribution system utilizing single point
    distributor or hub and laterals for maximum flowrates.
  • Operating pressure 20-125 psi / 138 – 861 kpa,
    operating temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w display for time of day, days
    until next regeneration, volume remaining, current flow rate
    and total volume used (totalizer).
  • Double backwash for optimum regeneration cleaning ability
    and salt efficiency.
  • 12 volt output AC transformer.
  • Duplex alternating motorized electronic control valve (2”).
  • 1 – 28 day override on control valve programming.
  • Brine tank salt grid for easy cleaning.
  • Brine tanks 24” x 50” or 30” x 50”c./w brine well and safety
    float to eliminate overflowing tanks.The brine tank has 800
    or 1000 lb water softening salt capacity.
  • 1 ¼” FPT drain line, ¾” FPT brine line.

Series EWS 2′ H DUPLEX Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 2” NPT inlet or outlet / 2 ½” Victaulic lead free brass epoxy
    coated control valve.
  • Electronic flow meters for each control valve accuracy plus
    or minus 5 percent, flow rate range 1.5 – 125 gpm, gallon
    range 10 – 999,000 and totalizer 1,000 – 999,999,000 gallons.
  • Service flow rates to 125 gpm, peak flow rates to
    150 gpm, backwash flow rates to 125 gpm.
  • Fully programmable and adjustable 9 cycle control
    valve that control backwash, slow/fast rinse, draw, refill,
    2nd backwash and service, up to 9 cycles.
  • Progressive flow, parallel flow, alternating
    on demand soft water.
  • System designs up to 4 vessels.
  • Cycles of operation – Cycle One backwash 1 – 95 minutes
    or off, Cycle Two brine draw 1 – 180 minutes or off,
    Cycle Three slow rinse 1 – 95 minutes or off, Cycle Four
    fast rinse 1 – 95 minutes or off, Cycle Five refill
    0.1 – 99 minutes or off, Cycle Six hold (service)
    1 – 480 minutes or off, three additional cycles forsecond backwash, slow rinse, fast rinse.
  • Four methods to initiate regeneration, meter immediate,
    meter delayed, time clock delayed or pressure differential.
  • 2” water distribution system utilizing hub and laterals for maximum flow rates.
  • Operating pressure 20 – 125 psi / 138 – 861 kpa.
  • Operating temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w removal front panel, digital
    display for time of day, days until next regeneration, volume
    remaining, current flow rate and total volume used (totalizer).
    All 9 cycles are adjustable in second level diagnostics for desired
    flow rates in each cycle.
  • Double backwash for optimum regeneration cleaning ability and salt efficiency.
  • 24 volt output AC transformer, 12 or 24 hour time clock.
  • Duplex alternating motorized electronic control valve (2”).
  • 1 – 28 day override on control valve program.
  • Brine tank 30” x 50” and 50” x 60” c/w brine well and safety float.
    The brine tank has salt capacity of 1,000 lbs and 4,500 lbs.
  • Optional 2” inlet and outlet motorized bypass valve.

Series EWS 2′ H Triplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 2” NPT inlet or outlet / 2 ½” Victaulic lead free brass epoxy
    coated control valve.
  • Electronic flow meters for each control valve accuracy plus
    or minus 5 percent, flow rate range 1.5 – 125 gpm, gallon
    range 10 – 999,000 and totalizer 1,000 – 999,999,000 gallons.
  • Service flow rates to 125 gpm, peak flow rates to
    150 gpm, backwash flow rates to 125 gpm.
  • Fully programmable and adjustable 9 cycle control
    valve that control backwash, slow/fast rinse, draw, refill,
    2nd backwash and service, up to 9 cycles.
  • Progressive flow, parallel flow, alternating
    on demand soft water.
  • System designs up to 4 vessels.
  • Cycles of operation – Cycle One backwash 1 – 95 minutes
    or off, Cycle Two brine draw 1 – 180 minutes or off,
    Cycle Three slow rinse 1 – 95 minutes or off, Cycle Four
    fast rinse 1 – 95 minutes or off, Cycle Five refill
    0.1 – 99 minutes or off, Cycle Six hold (service)
    1 – 480 minutes or off, three additional cycles forsecond backwash, slow rinse, fast rinse.
  • Four methods to initiate regeneration, meter immediate,
    meter delayed, time clock delayed or pressure differential.
  • 2” water distribution system utilizing hub and laterals for maximum flow rates.
  • Operating pressure 20 – 125 psi / 138 – 861 kpa.
    Operating temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w removal front panel, digital
    display for time of day, days until next regeneration, volume
    remaining, current flow rate and total volume used (totalizer).
    All 9 cycles are adjustable in second level diagnostics for desired
    flow rates in each cycle.
  • Double backwash for optimum regeneration cleaning ability and salt efficiency.
  • 24 volt output AC transformer, 12 or 24 hour time clock.
  • 1 – 28 day override on control valve program.
  • Brine tank 30” x 50” and 50” x 60” c/w brine well and safety float.The brine tank has salt capacity of 1,000 lbs and 4,500 lbs.
  • 2” inlet and outlet motorized bypass valve.

Series EWS 2′ H Quadplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 2” NPT inlet or outlet / 2 ½” Victaulic lead free brass epoxy
    coated control valve.
  • Electronic flow meters for each control valve accuracy plus
    or minus 5 percent, flow rate range 1.5 – 125 gpm, gallon
    range 10 – 999,000 and totalizer 1,000 – 999,999,000 gallons.
  • Service flow rates to 125 gpm, peak flow rates to
    150 gpm, backwash flow rates to 125 gpm.
  • Fully programmable and adjustable 9 cycle control
    valve that control backwash, slow/fast rinse, draw, refill,
    2nd backwash and service, up to 9 cycles.
  • Progressive flow, parallel flow, alternating
    on demand soft water.
  • System designs up to 4 vessels.
  • Cycles of operation – Cycle One backwash 1 – 95 minutes
    or off, Cycle Two brine draw 1 – 180 minutes or off,
    Cycle Three slow rinse 1 – 95 minutes or off, Cycle Four
    fast rinse 1 – 95 minutes or off, Cycle Five refill
    0.1 – 99 minutes or off, Cycle Six hold (service)
    1 – 480 minutes or off, three additional cycles forsecond backwash, slow rinse, fast rinse.
  • Four methods to initiate regeneration, meter immediate,
    meter delayed, time clock delayed or pressure differential.
  • 2” water distribution system utilizing hub and laterals for maximum flow rates.
  • Operating pressure 20 – 125 psi / 138 – 861 kpa.
  • Operating temperature 40°F – 110°F (5°C – 44°C).
  • Solid state microprocessor c/w removal front panel, digital
    display for time of day, days until next regeneration, volume
    remaining, current flow rate and total volume used (totalizer).All 9 cycles are adjustable in second level diagnostics for desired
    flow rates in each cycle.
  • Double backwash for optimum regeneration cleaning ability and salt efficiency.
  • 24 volt output AC transformer, 12 or 24 hour time clock.
  • 1 – 28 day override on control valve program.
  • Brine tank 30” x 50” and 50” x 60” c/w brine well and safety float.The brine tank has salt capacity of 1,000 lbs and 4,500 lbs.
  • 2” inlet and outlet motorized bypass valve.

Series EWS 3′ Duplex Commercial SoftenerView Spec. Sheet

    • 3” electronic microprocessor brass top mount control valve
      single or multi unit systems with interlocking control valves

Replacement Cartridges

Series EWS 3′ Triplex Commercial SoftenerView Spec. Sheet

    • 3” electronic microprocessor brass top mount control valve
      single or multi unit systems with interlocking control valves

Replacement Cartridges

  • Solid state electronic control processor c/w current flow rate,
    peak flow rate, totalizer, hours between last two regeneration,
    hours since last regeneration, volume remaining, remote start,
    time of day, cycle step times and flow meter size, remote
    lockout variable reserve.
  • Fully adjustable 5 cycle control valve with backwash, brining,
    slow rinse, rapid rinse, and service
  • Service flow rate up to 250 USGPM, peak flow rate up to 325
    USGPM, backwash flow rate up to 100 USGPM
  • pressure 20 – 125 PSI, operating temperature 34˚ F – 110˚ F
  • Nema 3R water resistant enclosure, no hard water bypass
  • Meter accuracy plus or minus 5 percent, salt grind for easy cleaning
  • Safety float to eliminate brine tank from overflowing
  • Drain line 2” NPT, Brine line 1” NPT, 3” Hub & Laterals

Series EWS 3′ Quadplex Commercial SoftenerView Spec. Sheet

Replacement Cartridges

  • 3” electronic microprocessor brass top mount control valve
    single or multi unit systems with interlocking control valves
  • Solid state electronic control processor c/w current flow rate,
    peak flow rate, totalizer, hours between last two regeneration,
    hours since last regeneration, volume remaining, remote start,
    time of day, cycle step times and flow meter size, remote
    lockout variable reserve.
  • Fully adjustable 5 cycle control valve with backwash, brining,
    slow rinse, rapid rinse, and service
  • Service flow rate up to 250 USGPM, peak flow rate up to 325
    USGPM, backwash flow rate up to 100 USGPM
  • pressure 20 – 125 PSI, operating temperature 34˚ F – 110˚ F
  • Nema 3R water resistant enclosure, no hard water bypass
  • Meter accuracy plus or minus 5 percent, salt grind for easy cleaning
  • Safety float to eliminate brine tank from overflowing
  • Drain line 2” NPT, Brine line 1” NPT, 3” Hub & Laterals