Series EWS 1' simplex Commercial CARBON FILTER
- 1” NPT inlet and outlet top mounted composite electronic control valve.
- Electronic flow meter with accuracy within plus or minus
5 percent, flow rate range 0.25 to 27 gpm. Gallons range
20 to 50,000 gallons 1000 to 9,999,000 totalizer. - Service flow rate up to 27 gpm, peak flow rate up
to 32 gpm, backwash flow rates up to 27 gpm. - Fully adjustable 6 cycle controls backwash, slow/fast
rinse and service. 2 additional cycles for backwash or rinse. - Cycles of operation. Cycle One backwash 6-12 minutes,
Cycle Two slow rinse 45-75 minutes, Cycle Three second
backwash 3-12 minutes, Cycle Four fast rinse 3-8 minutes, Cycle Five service. - Four methods to initiate regeneration, meter immediate,
meter delayed, time clock delayed or pressure differential. - 1” water distribution system utilizing single point distributor
or hub and laterals for maximum flow rates. - Operating pressure 20-125 psi / 138-861 kpa, operating
temperature 40°F – 110°F (5°C – 44°C). - Solid state microprocessor c/w display for time of day,
days until next regeneration, volume remaining, current flow
rate and total volume used (totalizer). - Double backwash for optimum regeneration cleaning ability.
- 12 volt output AC transformer. 12 or 24 hour time clock.
- 1 – 28 days override on control valve programming.
- 1” MPT drain line.
Series EWS 1' Duplex Commercial CARBON FILTER
- 1” NPT inlet and outlet top mounted composite electronic control valve.
- Electronic flow meter with accuracy within plus or minus
5 percent, flow rate range 0.25 to 27 gpm. Gallons range
20 to 50,000 gallons, 1000 to 9,999,000 totalizer. - Service flow rate up to 27 gpm, peak flow rate up to 32 gpm,
backwash flow rates up to 27 gpm. - Fully adjustable 6 cycle controls backwash, slow/fast rinse
and service. 2 additional cycles for backwash or rinse. - Cycles of operation. Cycle One backwash 6-12 minutes,
Cycle Two slow rinse 45-75 minutes, Cycle Three second
backwash 3-12 minutes, Cycle Four fast rinse 3-8 minutes, Cycle Five service. - Four methods to initiate regeneration, meter immediate, meter
delayed, time clock delayed or pressure differential. - 1” water distribution system utilizing single point distributor or hub
and laterals for maximum flowrates. - Operating pressure 20-125 psi / 138-861 kpa, operating temperature
40°F – 110°F (5°C – 44°C). - Solid state microprocessor c/w display for time of day, days until next regeneration,
volume remaining, current flow rate and total volume used (totalizer). - Double backwash for optimum regeneration cleaning ability.
- 12 volt output AC transformer. 12 or 24 hour time clock.
- Duplex alternating motorized electronic control valve (1”).
- 1 – 28 days override on control valve programming.
- 1” Drain Line.
Series EWS 1.5' Simplex Commercial CARBON FILTER
- 1 ½” NPT inlet and outlet top mounted lead free brass
epoxy coated control valve. - Electronic flow meter with accuracy within plus or minus
5 percent, flow rate range 0.5 to 60 gpm. Gallons range
500 to 250,000, totalizer 1 to 9,999,000 gallons. - Service flow rate up to 60 gpm, peak flow rate up
to 68 gpm, backwash flow rates up to 50 gpm. - Fully adjustable 6 cycle controls backwash, slow/fast
rinse and service. 2 additional cycles for backwash or rinse. - Cycles of operation. Cycle One backwash 1-20 minutes
or off, Cycle Two slow rinse 1-99 minutes or off, Cycle Three
second backwash 1-20 minutes or off, Cycle Four fast rinse
1-20 minutes or off, Cycle Five service. - Four methods to initiate regeneration, meter immediate,
meter delayed, time clock delayed or pressure differential. - 1 ½” water distribution system utilizing single point distributor
or hub and laterals for maximum flowrates. - Operating pressure 20-125 psi / 138-861 kpa, operating
temperature 40°F – 110°F (5°C – 44°C). - Solid state microprocessor c/w display for time of day,
days until next regeneration, volume remaining, current flow
rate and total volume used (totalizer). - Double backwash for optimum regeneration cleaning ability.
- 12 volt output AC transformer. 12 or 24 hour time clock.
- 1 – 28 days override on control valve programming.
- 1 1⁄4” FTP drain line.
Series EWS 1.5' Duplex Commercial CARBON FILTER
- 1 ½” NPT inlet and outlet top mounted lead free brass
epoxy coated control valve. - Electronic flow meter with accuracy within plus or minus
5 percent, flow rate range 0.5 to 60 gpm. Gallons range
500 to 250,000, totalizer 1 to 9,999,000 gallons. - Service flow rate up to 60 gpm, peak flow rate up to 68 gpm,
backwash flow rates up to 50 gpm. - Fully adjustable 6 cycle controls backwash, slow/fast rinse
and service. 2 additional cycles for backwash or rinse. - of operation. Cycle One backwash 1-20 minutes or off,
Cycle Two slow rinse 1-99 minutes or off, Cycle Three second
backwash 1-20 minutes or off, Cycle Four fast rinse 1-20
minutes or off, Cycle Five service. - Four methods to initiate regeneration, meter immediate,
meter delayed, time clock delayed or pressure differential. - 1 ½” water distribution system utilizing single point distributor
or hub and laterals for maximum flowrates. - Operating pressure 20-125 psi / 138-861 kpa, operating
temperature 40°F – 110°F (5°C – 44°C). - Solid state microprocessor c/w display for time of day, days
until next regeneration, volume remaining, current flow rate
and total volume used (totalizer). - Double backwash for optimum regeneration cleaning ability.
- 12 volt output AC transformer. 12 or 24 hour time clock.
- Duplex alternating motorized electronic control valve (1 1⁄2”).
- 1 – 28 days override on control valve programming.
- 1 1⁄4” FTP drain line.
Series EWS 2' L Simplex Commercial CARBON FILTER
- 2” NPT inlet and outlet top mounted lead free brass
epoxy coated control valve. - Electronic flow meter with accuracy within plus or minus
5 percent, flow rate range 1.5 to 75 gpm. Gallons range
500 to 250,000, totalizer 1 to 9,999,000 gallons. - Service flow rate up to 75 gpm, peak flow rate up to 88 gpm,
backwash flow rates up to 50 gpm. - Fully adjustable 6 cycle controls backwash, slow/fast rinse
and service. 2 additional cycles for backwash or rinse - Cycles of operation. Cycle One backwash 1-20 minutes or off,
Cycle Two slow rinse 1-99 minutes or off, Cycle Three second
backwash 1-20 minutes or off, Cycle Four fast rinse 1-20 minutes
or off, Cycle Five service. - Four methods to initiate regeneration, meter immediate, meter
delayed, time clock delayed or pressure differential. - 1 ½” water distribution system utilizing single point distributor
or hub and laterals for maximum flowrates. - Operating pressure 20-125 psi / 138-861 kpa, operating temperature
40°F – 110°F (5°C – 44°C). - Solid state microprocessor c/w display for time of day, days until
next regeneration, volume remaining, current flow rate and total
volume used (totalizer). - Double backwash for optimum regeneration cleaning ability.
- 12 volt output AC transformer. 12 or 24 hour time clock.
- 1 – 28 days override on control valve programming.
Series EWS 2' L Duplex Commercial CARBON FILTER
- 2” NPT inlet and outlet top mounted lead free brass epoxy
coated control valve. - Electronic flow meter with accuracy within plus or minus
5 percent, flow rate range 1.5 to 75 gpm. Gallons range
500 to 250,000, totalizer 1 to 9,999,000 gallons. - Service flow rate up to 75 gpm, peak flow rate up to 88 gpm,
backwash flow rates up to 50 gpm. - Fully adjustable 6 cycle controls backwash, slow/fast rinse
and service. 2 additional cycles for backwash and rinse - Cycles of operation. Cycle One backwash 1-20 minutes or
off, Cycle Two slow rinse 1-99 minutes or off, Cycle Three
second backwash 1-20 minutes or off, Cycle Four fast rinse
1-20 minutes or off, Cycle Five service. - Four methods to initiate regeneration, meter immediate,
meter delayed, time clock delayed or pressure differential. - 1 ½” water distribution system utilizing single point distributor
or hub and laterals for maximum flowrates. - Operating pressure 20-125 psi / 138-861 kpa, operating
temperature 40°F – 110°F (5°C – 44°C). - Solid state microprocessor c/w display for time of day, days
until next regeneration, volume remaining, current flow rate
and total volume used (totalizer). - Double backwash for optimum regeneration cleaning ability.
- Duplex alternating motorized electronic control valve (2”).
- 12 volt output AC transformer. 12 or 24 hour time clock.
- 1 – 28 days override on control valve programming.
- 1 1⁄4” FTP drain line.
Series EWS 2' H Duplex Commercial CARBON FILTER
- 2” NPT inlet or outlet / 2 ½” Victaulic lead free brass epoxy
coated control valve. - Electronic flow meters for each control valve accuracy plus or minus
5 percent, flow rate range 1.5 – 125 gpm, gallon range 10 – 999,000
and totalizer 1,000 – 999,999,000 gallons. - Service flow rates to 125 gpm, peak flow rates to 150 gpm,
backwash flow rates to 125 gpm. - Fully programmable and adjustable 9 cycle control valve that control
backwash, slow/fast rinse, 2nd backwash and service, up to 9 cycles. - Progressive flow, parallel flow, alternating.
- System designs up to 4 vessels.
- Cycles of operation – Cycle One backwash 1 – 95 minutes or off,
Cycle Two fast rinse 1 – 180 minutes or off, Cycle Three slow rinse
1 – 95 minutes or off, Cycle Four fast rinse 1 – 95 minutes or off,
Cycle Five hold (service) 1 – 480 minutes or off, four additional
cycles for additional backwash, slow rinse, fast rinse. - Four methods to initiate regeneration, meter immediate, meter
delayed, time clock delayed or pressure differential. - 2” water distribution system utilizing hub and laterals for maximum
flow rates. - Operating pressure 20 – 125 psi / 138 – 861 kpa.
- Operating temperature 40°F – 110°F (5°C – 44°C).
- Solid state microprocessor c/w removal front panel, digital display
for time of day, days until next regeneration, volume remaining,
current flow rate and total volume used (totalizer). All 9 cycles are
adjustable in second level diagnostics for desired flow rates in each cycle. - Double backwash for optimum regeneration cleaning ability.
- 24 volt output AC transformer, 12 or 24 hour time clock.
- Duplex alternating motorized electronic control valve (2”).
- 1 – 28 day override on control valve program.
- Optional 2” inlet and outlet motorized bypass valve.
Series EWS 2' H Triplex Commercial CARBON FILTER
- 2” NPT inlet or outlet / 2 ½” Victaulic lead free brass
epoxy coated control valve. - Electronic flow meters for each control valve accuracy
plus or minus 5 percent, flow rate range 1.5 – 125 gpm,
gallon range 10 – 999,000 and totalizer
1,000 – 999,999,000 gallons. - Service flow rates to 125 gpm, peak flow rates to 150 gpm,
backwash flow rates to 125 gpm. - Fully programmable and adjustable 9 cycle control valve
that control backwash, slow/fast rinse, 2nd backwash and
service, up to 9 cycles. - Progressive flow, parallel flow, alternating.
- System designs up to 4 vessels.
- Cycles of operation – Cycle One backwash 1 – 95 minutes
or off, Cycle Two fast rinse 1 – 180 minutes or off, Cycle
Three slow rinse 1 – 95 minutes or off, Cycle Four fast rinse
1 – 95 minutes or off, Cycle Five hold (service) 1 – 480
minutes or off, four additional cycles for additional backwash,
slow rinse, fast rinse. - Four methods to initiate regeneration, meter immediate,
meter delayed, time clock delayed or pressure differential. - 2” water distribution system utilizing hub and laterals for
maximum flow rates. - Operating pressure 20 – 125 psi / 138 – 861 kpa.
- Operating temperature 40°F – 110°F (5°C – 44°C).
- Solid state microprocessor c/w removal front panel, digital
display for time of day, days until next regeneration, volume
remaining, current flow rate and total volume used (totalizer).
All 9 cycles are adjustable in second level diagnostics for desired
flow rates in each cycle. - Double backwash for optimum regeneration cleaning ability.
- 24 volt output AC transformer, 12 or 24 hour time clock.
- 2” inlet and outlet motorized bypass valves.
- 1 – 28 day override on control valve program.
Series EWS 2' H Quadplex Commercial CARBON FILTER
- 2” NPT inlet or outlet / 2 ½” Victaulic lead free brass
epoxy coated control valve. - Electronic flow meters for each control valve accuracy
plus or minus 5 percent, flow rate range 1.5 – 125 gpm,
gallon range 10 – 999,000 and totalizer
1,000 – 999,999,000 gallons. - Service flow rates to 125 gpm, peak flow rates to 150 gpm,
backwash flow rates to 125 gpm. - Fully programmable and adjustable 9 cycle control valve
that control backwash, slow/fast rinse, 2nd backwash and
service, up to 9 cycles. - Progressive flow, parallel flow, alternating.
- System designs up to 4 vessels.
- Cycles of operation – Cycle One backwash 1 – 95 minutes
or off, Cycle Two fast rinse 1 – 180 minutes or off, Cycle
Three slow rinse 1 – 95 minutes or off, Cycle Four fast rinse
1 – 95 minutes or off, Cycle Five hold (service) 1 – 480
minutes or off, four additional cycles for additional backwash,
slow rinse, fast rinse. - Four methods to initiate regeneration, meter immediate,
meter delayed, time clock delayed or pressure differential. - 2” water distribution system utilizing hub and laterals for
maximum flow rates. - Operating pressure 20 – 125 psi / 138 – 861 kpa.
- Operating temperature 40°F – 110°F (5°C – 44°C).
- Solid state microprocessor c/w removal front panel, digital
display for time of day, days until next regeneration, volume
remaining, current flow rate and total volume used (totalizer).
All 9 cycles are adjustable in second level diagnostics for desired
flow rates in each cycle. - Double backwash for optimum regeneration cleaning ability.
- 24 volt output AC transformer, 12 or 24 hour time clock.
- 2” inlet and outlet motorized bypass valves.
- 1 – 28 day override on control valve program.
Series EWS 3' Duplex Commercial CARBON FILTER
- 3” NPT inlet and outlet lead free brass control valve, c/w Nema 3R enclosure is water resistant
- Electronic flow meters for each control valve, accuracy plus or minus 5 percent, flow rate 7 to 300 GPM
- Service flow rates to 250 GPM continuous (15 PSI Pressure Drop), peak flow rates to 325 GPM (25 PSI Pressure Drop)
- Fully adjustable 5 cycle control valve that controls upflow backwash, downflow brining, slow rinse, rapid rinse, and down flow service
- Progressive flow, parallel flow, alternating on demand treated water.
- Five methods to initiate regeneration: meter immediate, meter delayed, time clock delayed, pressure differential, or remote start
- 3” water distribution system utilizing hub and laterals for maximum flow rates
- Operating pressure 20 – 125 PSI / 138 – 861 KPA
- Operating temperature 40˚F – 110˚F (5˚C – 44˚C)
- System designs up to 4 vessels
- Electronic controller can network up to 4 vessels, field configurable for any flow meter, remote start, remote lockout, variable reserve, flow rate, peak flow rate, totalizer, hours between last two regenerations, hours since last regeneration, adjustable volume remaining, value position programming levels
- Time of day adjustment
- Quick programming – adjust hardness, regeneration,
time and day override - Master programming: configure value type, regeneration type, remote start/lock, US or European time/Volume display, system capacity safety factor, hardness, cycle
stop times, flow meter size, auxiliary delay operation - 24 volt output AC transformer, 7, 12 day clock or
meter initiated - Gravel under bedding for improved filtration
during regeneration
Series EWS 3' Triplex Commercial CARBON FILTER
- 3” NPT inlet and outlet lead free brass control valve, c/w Nema 3R enclosure is water resistant
- Electronic flow meters for each control valve, accuracy plus or minus 5 percent, flow rate 7 to 300 GPM
- Service flow rates to 250 GPM continuous (15 PSI Pressure Drop), peak flow rates to 325 GPM (25 PSI Pressure Drop)
- Fully adjustable 5 cycle control valve that controls upflow backwash, downflow brining, slow rinse, rapid rinse, and down flow service
- Progressive flow, parallel flow, alternating on demand treated water.
- Five methods to initiate regeneration: meter immediate, meter delayed, time clock delayed, pressure differential, or remote start
- 3” water distribution system utilizing hub and laterals for maximum flow rates
- Operating pressure 20 – 125 PSI / 138 – 861 KPA
- Operating temperature 40˚F – 110˚F (5˚C – 44˚C)
- System designs up to 4 vessel
- Electronic controller can network up to 4 vessels, field configurable for any flow meter, remote start, remote lockout, variable reserve, flow rate, peak flow rate, totalizer, hours between last two regenerations, hours since last regeneration, adjustable volume remaining, value position programming levels
- Time of day adjustment
- Quick programming – adjust hardness, regeneration,
time and day override - Master programming: configure value type, regeneration type, remote start/lock, US or European time/Volume display, system capacity safety factor, hardness, cycle
stop times, flow meter size, auxiliary delay operation - 24 volt output AC transformer, 7, 12 day clock or meter initiated
- Gravel under bedding for improved filtration during regeneration
Series EWS 3' Quadplex Commercial CARBON FILTER
- 3” NPT inlet and outlet lead free brass control valve, c/w Nema 3R enclosure is water resistant
- Electronic flow meters for each control valve, accuracy plus or minus 5 percent, flow rate 7 to 300 GPM
- Service flow rates to 250 GPM continuous (15 PSI Pressure Drop), peak flow rates to 325 GPM (25 PSI Pressure Drop)
- Fully adjustable 5 cycle control valve that controls upflow backwash, downflow brining, slow rinse, rapid rinse, and down flow service
- Progressive flow, parallel flow, alternating on demand treated water.
- Five methods to initiate regeneration: meter immediate, meter delayed, time clock delayed, pressure differential, or remote start
- 3” water distribution system utilizing hub and laterals for maximum flow rates
- Operating pressure 20 – 125 PSI / 138 – 861 KPA
- Operating temperature 40˚F – 110˚F (5˚C – 44˚C)
- System designs up to 4 vessels
- Electronic controller can network up to 4 vessels, field configurable for any flow meter, remote start, remote lockout, variable reserve, flow rate, peak flow rate, totalizer, hours between last two regenerations, hours since last regeneration, adjustable volume remaining, value position programming levels
- Time of day adjustment
- Quick programming – adjust hardness, regeneration,
time and day override - Master programming: configure value type, regeneration type, remote start/lock, US or European time/Volume display, system capacity safety factor, hardness, cycle
stop times, flow meter size, auxiliary delay operation - 24 volt output AC transformer, 7, 12 day clock or
meter initiated - Gravel under bedding for improved filtration during regeneration